Welcome to the official website of Shanghai Changhui Automation Engineering Co., Ltd.

tel.png  13917381936

Shanghai Changhui Automation Engineering Co., Ltd.

What are the basic structures of the aging house?

News

Contact

Contact person: Manager Zhang

Tel: 021-37910052

Mobile phone: 139 1738 1936

Address: No. 7155 Nanting Highway, Tinglin Town, Jinshan District, Shanghai

What are the basic structures of the aging house?

Date:2019-02-21 Author: Click:

What are the basic structures of an aging house?


1. There are two central relays: one on the left is used for converting exhaust signal: manual, automatic and defective exhaust; the other on the right is used for defective signal conversion.


2. Phase sequence protector: When the phase sequence is wrong or missing, the fault signal is output to the controller.


3. Contactors: power supply for heating pipe solid state relay.


4. Switching power supply 1: DC 24V for the temperature controller power supply.


5. Solid-state relay: located in the distribution box, according to the PID calculation of the temperature controller for heating pipe power supply.


6. Temperature sensor: PT100, 10m line length; provide temperature signal for temperature controller.


上海昌慧自动化工程有限公司Shanghai Changhui Automation Engineering Co., Ltd.


7. A set of air ducts: located in the interior of the room, with a set of heating pipes and a circulating fan on the upper part. During operation, the circulating fan sucks air from the bottom of the duct and blows air from the side of the duct.


8. Drainage and exhaust system: The exhaust outlet is located on the top of the aging room. The first exhaust fan is 0.37KW and 1400 rpm.


Room material: internal and external color steel or stainless steel plate, thermal insulation material: rock wool or PU.


Content area can be enlarged arbitrarily, easy to disassemble and assemble, and can be planned according to the size of customers'needs, and cooperate with the migration of customers when expanding factories.


Scientific air circulation planning, to prevent any dead angle, so that indoor temperature distribution is even.


Website:http://www.shchanghui.net/en/news/397.html

Label:

Recently browse: